Centerline of hall call buttons to be 42” AFF.
CBC 1116B.1.10 ADAAG 4.10.3
Provide visual and audible signal at each hoistway entrance indicating direction of travel.
Visual signal to be 2-1/2” x 2-1/2” & visible from proximity of hall call button.
Audible signal to sound once for “up” and twice for “down” direction.
Centerline of fixture to be 6’-0” AFF.
CBC 1116B.1.13 ADAAG 4.10.4
Passenger elevator landing jambs on all elevator floors to have the number of the floor designated by raised characters 2” in height with contracted grade 2 Braille located at 60” AFF on both sides of the door so they are visible from within the elevator. On grade level, provide a raised 5 pointed 2” star to the left of the raised character.
CBC 1116B.1.14
If a City is building a public staircase on City owned property a on 5 ft wide ROW about 200 ft long, must they comply with ADA? Since wheelchairs could not use a staircase on a 30-35 degree slope, must elevators be required?
I’m not sure what information you are requesting. Please contact me directly.
Do you have such information for wheelchair lifts?