Elevators

Centerline of hall call buttons to be 42” AFF.
CBC 1116B.1.10 ADAAG 4.10.3

Provide visual and audible signal at each hoistway entrance indicating direction of travel.

Visual signal to be 2-1/2” x 2-1/2” & visible from proximity of hall call button.

Audible signal to sound once for “up” and twice for “down” direction.

Centerline of fixture to be 6’-0” AFF.
CBC 1116B.1.13 ADAAG 4.10.4

Passenger elevator  landing jambs on all elevator floors to have the number of the floor designated by raised characters 2” in height with contracted grade 2 Braille located at 60” AFF on both sides of the door so they are visible from within the elevator.  On grade level, provide a raised 5 pointed 2” star to the left of the raised character.
CBC 1116B.1.14