Categories
- 01 Site Access
- 02 Path of Travel
- 03 Detectable Warnings
- 04 Parking
- 05 Curb Ramps
- 06 Ramps
- 07 Doors
- 08 Wheelchair Clearance
- 09 Stairs
- 10 Elevators & Lifts
- 11 Sanitary Facilities
- 12 Showers & Tubs
- 13 Fitting Rooms
- 14 Drinking Fountains
- 15 Employee Work Areas
- 16 Signs
- 17 Controls & Switches
- 18 Checkstands
- 19 Sales & Service Counters
- 20 Alarms
- 21 Telephones
- 22 Fixed & Built in Seating
- 23 Kitchens
- 24 Assembly Areas
- 24 ATM's & Gas Pumps
- 26 Restaurants
- 27 Medical Facilities
- 28 Libraries
- 29 Lodging
- 30 Transportation
- 31 Recreation Facilities
- 60 Visually Impaired
- CA Legislation
- California ADA
- Certified Access Specialist (CASp)
- Uncategorized
Tag Archives: Certified Access Specialist (CASp)
Signs – Pictorial Requirements
Pictorial symbol signs to be 6” min. in height. CBC 1117B.5.5.3 ISA to consist of white figure on blue background equal to Color #15090 in Fed. Standard 595B. CBC 1117B.5.8.1.1 All accessible building entrances to be identified with an International … Continue reading
Posted in 16 Signs
Tagged ADA, Certified Access Specialist, Certified Access Specialist (CASp), Signs
Leave a comment
Sinks
Provide 30”x48” clear floor space in front of sink to allow forward approach. Clear floor space to extend max. of 19” underneath the sink. Sink to be max. of 6-1/2” deep & mounted max. 34” above finish floor. Provide knee … Continue reading
Drinking Fountains
Provide “hi-low” drinking fountain, min. 18” and max. 19” in depth with clear knee space between bottom of apron and floor not less than 27” high, 30” wide and 8” deep from front edge of fountain. Provide toe clearance of … Continue reading
Fitting Rooms
Min. clear width of accessible doors to be 32” when door is open 90 degrees. CBC 1133B.2 Mirrors to be 18” wide, 54” tall, mounted with bottom edge 20” max. from floor. Mounted to provide view to person on bench … Continue reading
Showers
Min. dimen. for roll-in shower 60” x 30” with full opening on the long side. CBC 1115B.4.4.1.1 ½” max. threshold CBC 1115B.4.4.2 Two or more accessible showers in same facility to be constructed “opposite hand.” CBC 1115B.4.4.3
Sanitary Facilities
Doors cannot swing into clear floor space required for any fixture. CBC 1115B.3.1.2 ADAAG 4.23.2 Exception: In-swinging, side-opening water closet compartment door to comply with Fig. 11B-1B. CBC 1115B.3.1.2 If compartment has side opening door, provide 60”x60” clear space in … Continue reading
Elevators
Centerline of hall call buttons to be 42” AFF. CBC 1116B.1.10 ADAAG 4.10.3 Provide visual and audible signal at each hoistway entrance indicating direction of travel. Visual signal to be 2-1/2” x 2-1/2” & visible from proximity of hall call … Continue reading
Stair Treads / Risers
Stair treads to be no less than 11”. Risers to be 7” max. & 4” min. CBC 1133B.4.5
Posted in 09 Stairs
Tagged ADA, California ADA, Certified Access Specialist, Certified Access Specialist (CASp), Stair
Leave a comment
Wheelchair Turning Space
Min. clear wheelchair turning width is 60” dia. circle or a “T” shaped space. CBC 1118B.1 ADAAG 4.2.3
Door Closers
Door closers to be adjusted to close from an open position of 70 degrees in not less than 3 seconds to a point 3” from the latch. CBC 1133B.2.5.1 ADAAG 4.13.10