Tag Archives: California ADA
Transportation Facilities
Transit stations – platform edges bordering drop-off to have detectable warnings (24” to 36” wide) running the full length of the platform drop-off. Provide directional texture at platform boarding locations. CBC 1121B.3.1.8 Detectable warnings at platform edges to be 24″ … Continue reading
Temporary Lodging
Accessible sleeping rooms to have 36” clear width along both sides of bed, except where 2 beds are provided, requirement can be met with 1, 36” aisle between beds. Also provide clear space under bed for personal lift device, (extending … Continue reading
Libraries
Open book stacks to be on an accessible route, normal height with main aisles no less than 44” & end aisles no less than 36”. CBC 1106B.4.2
Medical Facilities
Each bedroom to have 60” diameter clear turning space or “T” shaped space. 36” clear space at each side of bed. Accessible door. CBC 1109B.4
Restaurants & Cafeterias
Food service aisles to be 36” min. clear width with a preferred width of 42”. Tray slides to be no higher than 34” above finish floor. CBC 1104B.5.5 2010 ADA 904.5.2
Gas Pumps
Fuel Dispensing Facilities – highest part of card reader to not exceed 54”. CBC 1104C.1 Max. high side reach to be 48”. Min. low side reach to be 15” with 10” max. depth of obstruction. 2010 ADA 308.3 Gas pump … Continue reading
ATM’s & Gas Pumps
If parallel approach is possible, & reach depth does not exceed 10”, operable part of all controls to be max. 48” above finish floor. CBC 1117B.7.3 Max. high side reach to be 48”. Min. low side reach to be 15” … Continue reading
Assembly Areas
Min. number of Accessible Seating Spaces Seating # of Wheelchair Capacity Seating Spaces 4 – 25 1 1 26 – 50 2 1 51 – 300 4 1 301 – 500 6 When seating capacity exceeds 500, one additional wheelchair … Continue reading
Kitchens
U-shaped kitchens with parallel approach at range or cooktop to have min. clear width of 60” CBC 1133A.2.1 U-shaped kitchens with cooktop or sink located at base of U w/ 30” wide knee space to a height of 27” AFF … Continue reading
Posted in 23 Kitchens
Tagged ADA, California ADA, Certified Access Specialist, Certified Access Specialist (CASp), Kitchen
2 Comments
Built-In Tables
Provide clear floor space at fixed tables or counters. Clear floor space to overlap knee space 19” max. CBC 1122B.2 Provide knee clearance 27” high, 30” wide & 19” deep. Exception: Knee clearance not required at checkout counter or service … Continue reading