Tag Archives: ADA

Signs – Tactile Requirements

Tactile signs & pictorial symbols: Pictorial symbol signs to have verbal description placed directly below pictogram.  Outside dim. of pictogram to be 6”. (Note: no specific requirement for size of symbol or ISA.) Characters to be raised 1/32”, to be … Continue reading

Posted in 16 Signs | Tagged , , | 3 Comments

Barrier Removal in Existing Facilities

Where “barrier removal” is undertaken – strictly to address accessibility issues and not part of a renovation – the barrier removal may comply with the requirements of either the 1991 ADA or the 2010 ADA.  It is not necessary for … Continue reading

Posted in California ADA | Tagged , , , , | 1 Comment

Parking – International Symbol of Accessibility (ISA)

The CBC requirement for the International Symbol of Accessibility (ISA) that’s painted in an accessible parking stall – states that the symbol is to be a minimum of 36″ x 36″ CBC 1129B.4.2

Posted in 04 Parking, 16 Signs | Tagged , , , , , , , | 7 Comments

Recreation Facilities

Participation areas including: Tennis, racquetball & handball courts, gymnasium floor areas & general exercise rooms, basketball, volleyball, badminton courts and bowling lanes, athletic team rooms, facilities, playing fields and running tracks to be open to individuals with disabilities. CBC 1104B.4.3 … Continue reading

Posted in 31 Recreation Facilities | Tagged , , , , | 14 Comments

Transportation Facilities

Transit stations – platform edges bordering drop-off to have detectable warnings (24” to 36” wide) running the full length of the platform drop-off.  Provide directional texture at platform boarding locations. CBC 1121B.3.1.8 Detectable warnings at platform edges to be 24″ … Continue reading

Posted in 30 Transportation | Tagged , , , , | Leave a comment

Temporary Lodging

Accessible sleeping rooms to have 36” clear width along both sides of bed, except where 2 beds are provided, requirement can be met with 1, 36” aisle between beds. Also provide clear space under bed for personal lift device, (extending … Continue reading

Posted in 29 Lodging | Tagged , , , , , | Leave a comment

Libraries

Open book stacks to be on an accessible route, normal height with main aisles no less than 44” & end aisles no less than 36”. CBC 1106B.4.2

Posted in 28 Libraries | Tagged , , , , | Leave a comment

Medical Facilities

Each bedroom to have 60” diameter clear turning space or “T” shaped space. 36” clear space at each side of bed. Accessible door. CBC 1109B.4

Posted in 27 Medical Facilities | Tagged , , , , , | 1 Comment

Restaurants & Cafeterias

Food service aisles to be 36” min. clear width with a preferred width of 42”.  Tray slides to be no higher than 34” above finish floor. CBC 1104B.5.5  2010 ADA 904.5.2

Posted in 26 Restaurants | Tagged , , , | 2 Comments

Gas Pumps

Fuel Dispensing Facilities – highest part of card reader to not exceed 54”. CBC 1104C.1 Max. high side reach to be 48”. Min. low side reach to be 15” with 10” max. depth of obstruction. 2010 ADA  308.3 Gas pump … Continue reading

Posted in 24 ATM's & Gas Pumps | Tagged , , , , | Leave a comment